A closer look at the measurement chain: A holistic approach to sensor technology and CAN communication
published in: SENSOR+TEST – The innovation magazine 3/2026
Precise sensor technology alone is not enough: Only when measured values are reliably transmitted can a reliable system status be established. GEMAC combines dynamic tilt measurement with physical CAN diagnostics, thereby enabling a comprehensive analysis of the measurement chain—from motion detection to the control unit.
What good is a precise measurement if it is distorted by motion or does not reach the control unit reliably? Especially in dynamic applications, sensor technology and communication must be considered together. This is because there is an entire measurement chain between a system’s actual motion and its processing by the control unit: The sensor detects the physical state, the CAN network transmits the data, and the control unit processes it. Errors can occur at both levels – in the measurement as well as during transmission.
When developing and diagnosing electronic systems, it is therefore not enough to consider only the sensor or only CAN communication. What matters most is how they work together: How reliably is motion detected? How does the signal change under dynamic conditions? And does the information subsequently reach the control unit with the expected quality? It is precisely at this interface that sensor technology and physical CAN diagnostics converge.
Measuring inclination under dynamic conditions
Determining a machine’s tilt angle may seem straightforward at first. In a static measurement, the orientation can be derived from the direction of Earth’s acceleration. However, as soon as a machine moves, gravity and dynamic accelerations overlap. Vibrations, travel movements, and acceleration and braking maneuvers can affect the measurement.
With the MOTUS family, GEMAC develops and manufactures sensors for a variety of inclination and motion detection requirements. Static versions enable precise detection of machine orientation, while dynamic sensors combine angle measurement with intelligent filtering technology. For applications in which other motion parameters are relevant in addition to inclination, inertial measurement units (IMUs) are available. They measure acceleration and rotation rate, thereby enabling a more comprehensive description of machine motion.
A key advantage of MOTUS sensors lies in their customizable nature: Depending on the requirements, GEMAC fine-tunes sensor parameters and filters for each specific application and adapts connectors and cable lengths to the installation conditions. Sensor fusion and filtering algorithms also help reduce the impact of vibrations and dynamic movements on the angular data. The result is a sensor solution tailored to the specific application – from accuracy and measurement range to the required dynamic performance.

Reliable data transmission over the Canbus
However, the sensor’s measured value is only the first step in the measurement chain. In an electronically networked system, the information must then be reliably transmitted via the fieldbus to the respective control unit. CAN has been the established standard for this for many years. With CAN FD, an enhanced version of the CAN protocol, however, the requirements for the physical quality of the communication are increasing.
Higher data rates and shorter bit times reduce the time margins. As a result, signal reflections, interference, poor termination, and problems with cables or connectors can impair signal quality and thus the reliability of communication. In such cases, a diagnosis that considers only the transmitted telegrams falls short: A telegram may appear correct at the protocol level, while the electrical signal already exhibits quality issues.
This is exactly where GEMAC’s physical CAN diagnostics come into play. The CAN bus tester GT3 provides insight into both levels of communication: It shows what is happening at the protocol level while simultaneously revealing the quality of the electrical signal. In addition to the transmitted telegrams, signal waveforms and the temporal characteristics of the communication can also be analyzed. This reveals whether the cause of an error lies at the logical or physical level.
From suspicion to cause
This consideration is particularly relevant for development, commissioning, and service when errors occur only sporadically or cannot be clearly attributed to a specific component. A communication problem is not necessarily caused by a software error or a faulty telegram. The physical transmission itself may also be the cause.
By analyzing log data and electrical signal quality together, engineers can significantly reduce the time required to identify the root cause of an issue. Instead of replacing individual components one by one, you can perform targeted checks: for example, do the signal shape, temporal characteristics, and bus physics match, or are there any anomalies? This creates a solid foundation for further troubleshooting.
For this analysis, the GT3 features a separate measurement head that is connected directly to the bus. This allows measurements to be taken directly at the point where communication occurs. For the subsequent evaluation of the signals, the system includes, among other features, a 12-bit, two-channel oscilloscope as well as functions for analyzing CAN Classic and CAN FD signals.
One measurement chain, two perspectives
Sensor technology and fieldbus diagnostics are therefore not separate topics. They constitute two levels of the same electronic system architecture. The sensor provides information about the physical world: How much is a system tilting? How is it moving? What accelerations and rotational speeds are occurring? The fieldbus then transmits this information through the electronic network. There, the signal must be transmitted not only correctly at the protocol level but also reliably at the physical layer.
Dynamic applications in particular illustrate why these two levels go hand in hand: No matter how precisely a sensor measures, if its data does not reach the control unit reliably, a reliable system status cannot be determined. Conversely, even error-free CAN communication is of no use if the underlying measurement data is distorted by dynamic influences. What does this mean in practice? The entire measurement chain – from the physical measurement value to the transmission – must be considered and evaluated. This is just as relevant for the development of new machines and systems as it is for commissioning, troubleshooting, and subsequent maintenance.
Measurement technology for real-world applications
GEMAC develops and manufactures sensors and measurement technology for industrial applications. Its product portfolio includes inclination sensors and IMUs designed to meet a range of accuracy and dynamic performance requirements, as well as solutions for analyzing and evaluating CAN communication – from the protocol level down to physical signal quality.
In this way, GEMAC combines two key aspects of modern electronic systems: precise measurement data and reliable data transmission. For the user, this results in a comprehensive view of the measurement chain – from motion detection to data transmission to the control unit.